We have free demos of our Fire-Inspector-II study materials for your reference, as in the following, you can download which Fire-Inspector-II exam materials demo you like and make a choice. We have three versions of our Fire-Inspector-II exam guide, so we have according three versions of free demos. Therefore, if you really have some interests in our Fire-Inspector-II Study Materials, then trust our professionalism, we promise a full refund if you fail exam.
People are very busy nowadays, so they want to make good use of their lunch time for preparing for their Fire-Inspector-II exam. If you choice our Fire-Inspector-II exam question as your study tool, you will not meet the problem. Because the app of our Fire-Inspector-II exam prep supports practice offline in anytime. If you buy our products, you can also continue your study when you are in an offline state. You will not be affected by the unable state of the whole network. You can choose to use our Fire-Inspector-II Exam Prep in anytime and anywhere
>> Fire-Inspector-II Test Vce <<
Our company VerifiedDumps has been putting emphasis on the development and improvement of our Fire-Inspector-II test prep over ten year without archaic content at all. So we are bravely breaking the stereotype of similar content materials of the Fire-Inspector-II Exam, but add what the exam truly tests into our Fire-Inspector-II exam guide. So we have adamant attitude to offer help rather than perfunctory attitude. It will help you pass your Fire-Inspector-II exam in shortest time.
NEW QUESTION # 78
A bowling center with 25 lanes and 3,500 sq. ft. of additional area calculates to a maximum occupant load of how many people?
Answer: D
Explanation:
To determine the maximum occupant load for a bowling center with 25 lanes and 3,500 sq. ft. of additional area, we use the occupant load factor from 2021 IBC Table 1004.5.
Step 1: Calculate the Occupant Load for Bowling Lanes
IBC Table 1004.5 assigns 50 sq. ft. per person for bowling lanes and associated seating areas.
With 25 lanes, assuming 100 sq. ft. per lane (standard industry measurement for lane width and approach area):
25×(10050)=25×2=50 occupants25 imes left( rac{100}{50} ight) = 25 imes 2 = 50 ext{ occupants}
25×(50100)=25×2=50 occupants
Step 2: Calculate the Occupant Load for Additional Area
Additional 3,500 sq. ft. area follows a general occupant load factor of 15 sq. ft. per person (assembly without fixed seats):
3,50015=233.3 occupants#234 (rounded)rac{3,500}{15} = 233.3 ext{ occupants} approx 234 ext{ (rounded)}153,500=233.3 occupants#234 (rounded) Final Calculation:
50+184=234 occupants50 + 184 = 234 ext{ occupants}50+184=234 occupants Reference to Fire Inspector Documentation:
1. 2021 International Building Code (IBC) - Table 1004.5 (Occupant Load Factor) Bowling lanes require 50 sq. ft. per person.
Assembly areas without fixed seats use 15 sq. ft. per person.
2. 2021 International Fire Code (IFC) - Section 1004.1.2 (Areas without Fixed Seating) When calculating occupant load, areas without fixed seating must be divided by the appropriate occupant load factor.
Detailed Explanation of Answer Choices:
Option A (Incorrect): 125 is too low based on correct load factor calculations.
Option B (Correct): 234 is the correct calculation using IBC Table 1004.5.
Option C (Incorrect): 500 is too high based on the available space.
Option D (Incorrect): 625 significantly overestimates the actual occupant load.
Thus, the correct and verified answer is: B. 234.
NEW QUESTION # 79
Existing elevators in a four-story office building which are intended for use by emergency personnel for fire- fighting or rescue purposes must comply with which of the following standards?
Answer: C
Explanation:
Reference to Elevator Safety and Firefighter Use:
ASME A17.1 (Safety Code for Elevators and Escalators) establishes the safety requirements for elevators, including those designated for firefighter and emergency personnel use.
The International Fire Code (IFC) and NFPA 101 (Life Safety Code) both reference ASME A17.1 when addressing elevator safety and firefighter access.
Firefighter Access and Operation Requirements:
ASME A17.1, Section 2.27 covers Firefighter Emergency Operations (FEO), which includes:
Phase I Operation (Automatic recall of elevators to a designated floor upon activation of fire alarms).
Phase II Operation (Manual override by firefighters for rescue and suppression operations).
IFC 607.1 (2021 Edition) mandates that fire service access elevators comply with ASME A17.1 for firefighter use in high-rise and multi-story buildings.
Clarification of Incorrect Answer Choices:
A: UL 803 # Incorrect
UL 803 is not related to elevator fire safety; it pertains to electrical control panels for industrial applications.
B: NFPA 70 (National Electrical Code) # Incorrect
While NFPA 70 covers electrical wiring and circuits, it does not specifically regulate elevator emergency operations.
D: ASME A17.3 # Incorrect
ASME A17.3 is the Safety Code for Existing Elevators and Escalators, which applies to retrofits and upgrades, but ASME A17.1 is the primary code for operational and emergency use elevators.
Conclusion:
The correct and verified answer is C (ASME A17.1) because it specifically outlines the requirements for firefighter and emergency personnel elevator use, ensuring compliance with the IFC and NFPA codes.
NEW QUESTION # 80
Battery-charging areas for industrial trucks shall be protected with portable fire extinguishers which have a minimum rating of:
Answer: C
Explanation:
Battery-charging areas for industrial trucks (such as forklifts) present a fire hazard due to the potential for flammable hydrogen gas buildup and electrical malfunctions. To mitigate this risk, portable fire extinguishers with a minimum rating of 40-B:C are required.
Reference to Fire Inspector Documentation:
1. 2021 International Fire Code (IFC) - Section 309.5 (Fire Extinguishers for Battery-Charging Areas) IFC 309.5 states that battery-charging areas must have a portable fire extinguisher with a minimum rating of
40-B:C to handle potential electrical and flammable liquid fires.
The B rating covers flammable liquid fires (such as battery electrolyte leaks), while the C rating ensures it is safe for electrical fires.
2. NFPA 10 - Standard for Portable Fire Extinguishers (2022 Edition)
NFPA 10, Table 6.3.1.1 outlines that industrial battery-charging areas must have at least one extinguisher rated 40-B:C.
This ensures adequate fire suppression capability for both electrical and flammable liquid hazards.
Detailed Explanation of Answer Choices:
Option A (Incorrect): 4-A:20-B:C includes a higher A-rating (for ordinary combustibles), but 20-B:C is below the required 40-B:C.
Option B (Incorrect): 3-A:40-B:C exceeds the B:C requirements but adds an unnecessary A-rating, which is not specified in the code.
Option C (Incorrect): 2-A:10-B:C is insufficient, as it does not meet the 40-B:C minimum requirement.
Option D (Correct): 40-B:C is the correct and minimum required rating per IFC 309.5 and NFPA 10.
Thus, the correct and verified answer is: D. 40-B:C.
NEW QUESTION # 81
All new building construction must have installed an approved water supply for fire protection which provides a minimum of:
Answer: B
Explanation:
All new building construction must have an approved water supply that meets the minimum fire flow requirements necessary for fire protection. The exact fire flow depends on factors such as building size, occupancy type, construction materials, and hazard levels.
Reference to Fire Inspector Documentation:
1. 2021 International Fire Code (IFC) - Section 507.1 (Required Water Supply) IFC 507.1 states that an approved water supply capable of providing the required fire flow must be installed in all new construction projects.
The required fire flow varies based on building classification and must be determined by the authority having jurisdiction (AHJ).
2. 2021 IFC - Appendix B (Fire-Flow Requirements for Buildings)
Table B105.1(2) provides fire flow requirements based on construction type and building area.
Fire flow must be calculated according to the ISO (Insurance Services Office) Fire Suppression Rating Schedule.
Detailed Explanation of Answer Choices:
Option A (Correct): The fire flow requirement is determined based on the building and fire protection needs, making this the correct answer.
Option B (Incorrect): A static pressure of 40 psi at each hydrant is not a universal requirement, as fire flow is the primary factor.
Option C (Incorrect): A static pressure of 60 psi is not the fire code's general requirement; fire flow is the priority.
Option D (Incorrect): 250 gallons per minute (GPM) at a fire-access outlet is not an overall fire code requirement for all buildings-it depends on the structure's classification.
Thus, the correct and verified answer is: A. The required fire flow for fire protection.
NEW QUESTION # 82
Evidence of a fire inspection report being written and delivered to the person in charge of the property:
Answer: D
Explanation:
Fire Inspection Report as Legal Documentation
A fire inspection report serves as an official record of inspection findings, compliance violations, and corrective actions required.
It provides documented evidence that can be used in legal proceedings if enforcement actions are necessary.
2. Legal Basis and ICC Reference
According to the International Fire Code (IFC) and NFPA Standards, a properly documented inspection report ensures that violations are enforceable in court.
The ICC Fire Inspector Study Guide (2021) emphasizes that an inspection report is a critical legal document that supports the fire department or authority having jurisdiction (AHJ) in case of disputes or appeals.
3. Retention of Reports (Why Other Options Are Incorrect)
Option B (must be copied to the building code official) - Not necessarily required unless local jurisdiction mandates coordination between fire and building code officials.
Option C (must be copied to the city manager or mayor's office) - Fire inspection reports are not typically sent to city administration unless they involve significant violations or policy concerns.
Option D (must be retained by the code official for a minimum of three years) - While record retention is required, the period varies by jurisdiction (some require 3 years, others more), making this an incomplete and less universally correct answer.
Reference Sources:
ICC Fire Inspector II Study Guide (2021)
International Fire Code (IFC) 2021 Edition
NFPA 1031: Standard for Professional Qualifications for Fire Inspector and Plan Examiner
NEW QUESTION # 83
......
Our three versions of Fire-Inspector-II study materials are the PDF, Software and APP online. They have their own advantages differently and their prolific Fire-Inspector-II practice materials can cater for the different needs of our customers, and all these Fire-Inspector-II simulating practice includes the new information that you need to know to pass the test for we always update it in the first time. So you can choose them according to your personal preference.
Fire-Inspector-II Valid Exam Vce Free: https://www.verifieddumps.com/Fire-Inspector-II-valid-exam-braindumps.html
When you have a lot of eletronic devices, you definitly will figure out the way to study and prepare your Fire-Inspector-II exam with them, Yes you read it right, If our Fire-Inspector-II exam dumps didn't help you pass, we will issue a refund - no other questions asked the best, VerifiedDumps Fire-Inspector-II Valid Exam Vce Free provides International Code Council Fire-Inspector-II Valid Exam Vce Free certification exam questions for desktop computers, We promise you that if you fail to pass the exam after using Fire-Inspector-II training materials of us, we will give you full refund.
Full of relevant and insightful information, Shuja, Jochen Krebs, When you have a lot of eletronic devices, you definitly will figure out the way to study and prepare your Fire-Inspector-II Exam with them.
Yes you read it right, If our Fire-Inspector-II exam dumps didn't help you pass, we will issue a refund - no other questions asked the best, VerifiedDumps provides International Code Council certification exam questions for desktop computers.
We promise you that if you fail to pass the exam after using Fire-Inspector-II training materials of us, we will give you full refund,Some people slide over ticklish question habitually, Fire-Inspector-II but the experts help you get clear about them and no more hiding anymore.